The Trio CAN16 Input module offers a compact DIN rail mounted output expansion capability for all Trio Motion Coordinators.
Up to 16 P318 modules may be connected to the CAN network which may be up to 100m long.
This provides 256 distributed input channels at 24Vdc level. All input points are high level (24V in = ON) and completely isolated from the CANbus.
P318 modules may be mixed on the same bus, with other types in the Trio CAN I/O range. The Trio CANbus I/O expansion can considerably reduce machine wiring.
Inputs | CAN link for up to 16 modules over 100m @ 500kHz |
Configuration | 16 input channels |
Protection | Outputs are overcurrent and over temperature rated |
Indicators | Individual status LED’s |
Address Setting | Via DIP switches |
Power Supply | 24V / 1.5W |
Mounting | DIN rail mount |
Size | 26mm wide x 85mm deep x 130 mm high |
Weight | 168g |
CAN | 500kHz, Up to 256 expansion output channels |
EMC | EN61000-6-2 (2005) Industrial Noise Immunity/ EN61000-6-4 (2007) Industrial Noise Emissions. |
CAN protocol | Trio CANI/O or CANopen DS401 |
RoHs, UL | Compliant |
Tagged CANopen IO, IO digital IP